CITEL
Test Facilities
Jobs & Career
About us
Locations
GTC
Lightning Surges
Citel's VG Technology
International Standards
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Products
AC Power
Radiocommunication
Telecom
Miscellaneous
GDT
Dataline
Photovoltaic
LED
Applications
Security Systems
Wind Turbine Installation
Industrial Installation
Datacenter
Surge protection for LED-lighting systems
Photovoltaic installations
Gas Discharge Tubes and Gas Filled Spark Gaps
Surge protection for E-mobility
Surge protection for cell phone communication
Water treatment
Services
Information
Order form
Selection guide
Partner
Toggle Dropdown
Contact Citel
Privacy policy
Our partners in Europe
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
GDT
Accessories
GDT
3-electrode
BMSQ CMS (T&R) 230/20
3-electrode GDT
BMSQ CMS (T&R) 230/20
Part Number:
929925701
The smallest 2-electrode GDT
No radioactive
ITU-K12 compliant
Surface Mounting Device: electrod anti-rolling
Tape & Reel Packaging
Datasheet
Tender specifications
Contact Us
CITEL BM surge arresters are 3-electrode gas discharge tubes designed in ceramic technology and created to protect telecommunication or computer equipment, The reduced size of the BM series enables the implementation in limited space applications (small connector blocks...), SMD mounting (BM CMS type) or PCB mounting (with lead termination : BMS). BM could be provide with external fail-safe mechanism (BMC type) and is available in several DC sparkover voltages.
Select another reference:
BM 150/20
BM 230/20
BM 350/20
BM 420/20
BM 500/20
BM 90/20
BM C 230/15
BM C 350/20
BMSQ CMS (T&R) 230/20
BMSQ CMS (T&R) 420/20
BMSQ CMS (T&R) 90/20
BMSQ CMS 230/20
BMSQ CMS 90/20
BMSQ CMS FL (T&R) 230/20
BMSQ CMS FL (T&R) 420/20
Electrical Properties
Mechanical Properties
Norms
Schemas
DC sparkover voltage (100V/s)
184-276 V
DC spark voltage tolerance (100V/s)
+/- 20%
Maximum impulse sparkover voltage (1kV/µs)
≤ 680 V
Nominal discharge current
In
10 kA
Total Maximum discharge current
Imax Total
10 kA
Impulse current by pole
Iimp
2 kA
Impulse discharge current
2 kA
Max. capacitance
C
<0.5 pF
Insulation resistance
IR
≥10 GOhms
Arc Voltage
≤ 25 V
Glow-to-arc transition current
0.5 A
Glow voltage
≤ 100 V
AC discharge current (50Hz)
10 A
DC Holdover voltage
>80 V
Technology
Gas discharge tube
Mounting
Surface Mounting Device
Operating and storage temperature
-40°C / +90°C
Tape&Reel Version
Standard version
Dimensions
See diagram
Standards compliance
IEC 61643-311
Certification
UL Recognized / ROHS
RohS compliance
Yes
×
Read more