Surge protector for LED lighting system Class 1
DLPM1-230L
Part Number: 355913
- Type 2 (or 3) surge protectors for LED classe I
- Mechanical status indicator
- Very compact (low profile)
- DIN rail mounting
- Screw terminal connection
- AC line Disconnection in end of life
- EN 61643-11 compliance
The DLPM range is a series of DIN-mount AC surge protector designed to be installed inside the cutouts: his compact size and lower height make it compatible with the DIN rail mounting of its enclosures. This range has a mechanical disconnect indicator.
Select another reference:
SPD type | 2 (or 3) | |
Network | 220-240 V single-phase | |
AC system | TT/TN | |
Nominal line voltage | Un | 230-277 Vac |
Max. AC operating voltage | Uc | 320 Vac |
Max. load current | IL | 10 A |
Temporary Over Voltage (TOV) Charasteristics - 5 sec. | UT | 335 Vac withstand |
Temporary Over Voltage (TOV) Charasteristics - 120 mn | UT | 440 Vac disconnection |
Temporary Over Voltage N/PE (TOV HT) | UT | 1200 V/300A/200 ms disconnection |
Residual Current | Ipe | None |
Nominal discharge current | In | 5 kA |
Max. discharge current | Imax | 10 kA |
Total Maximum discharge current | Imax Total | 20 kA |
Withstand on Combination waveform IEC 61643-11 | Uoc | 10 kV / 5 kA |
Withstand on overvoltages IEEE C62.41.1 | 10 kV / 10 kA | |
Protection mode(s) | Common/Differential mode | |
Protection level L/N | Up L/N | 1.5 kV |
Protection level L/PE | Up L/PE | 1.5 kV |
Admissible short-circuit current | Isccr | 10 000 A |
Technology | MOV+GDT | |
Connection to Network | Screw terminal 2.5 mm² max. Earthing conductor 2 mm² - length 60 cm | |
Mounting | Symmetrical rail 35 mm (DIN 60715) | |
Housing material | Thermoplastic UL94 V-0 | |
Operating temperature | Tu | -40/+85°C |
Protection rating | IP20 | |
Failsafe mode | AC network cutt-off | |
Disconnection indicator | Red Indicator + AC line disconnection | |
Voltage/operating indicator | Green Indicator | |
Remote signaling of disconnection | No | |
Dimensions | See diagram |
Standards compliance | EN 61643-11 / IEC 61643-11 | |
Certification | CB / EAC |
Thermal disconnector | Internal | |
Installation ground fault breaker | Type 'S' or delayed |