CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Photovoltaic
Type 1 PV surge protector
DS50VGPV-1000G/12KT1
Type 1+2 PV surge protector
DS50VGPV-1000G/12KT1
Part Number
482303
Type 1+2 surge protector for Photovoltaic
VG Technology
No leakage, no operating currents
Improved life expectancy
Impulse currents Iimp/Itotal: 6.25/12.5 kA (10/350µs)
Common/Differential mode protection
Pluggable module
Remote signaling (option)
UL1449 ed.5 compliance
IEC 61643-31, EN 61643-31 certified
Datasheet
CITEL_Certif_EU_DS50xx10KT1_DS50xx12KT1 .pdf
Installation Sheet
Tender specifications
Contact Us
DS50VGPV-1000G/12KT1 are type 1+2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. The DS50VGPV-1000G/12KT1 SPDs incorporates CITEL's exclusive patented 'VG technology' guarantying a total absence of leakAge current and maximum reliability.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Network
PV network 1000 Vdc
Nominal PV voltage
Uocstc
1000 Vdc
Max. PV operating voltage
Ucpv
1200 Vdc
Residual Current
Leakage current to Ground
Ipe
None
PV Permanent Operating current
Current consumption at Ucpv
Icpv
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
15 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
60 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
6.25 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
12.5 kA
Current withstand short circuit PV
Iscpv
15 000 A
Protection mode(s)
Common/Differential mode
Protection level +/-
@ In (8/20µs)
Up
5.1 kV
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
2.8 kV
Technology
VG Technology (MOV+GSG)
Connection to Network
By screw terminals: 2.5-25mm²
Format
Plug-in modular box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Disconnection indicator
2 mechanical indicators
Spare module(s)
DSM50VGPV-1000G/12KT1 / DSM50VGPV-1000GPE/12KT1
Remote signaling of disconnection
Option DS50VGPVS-1000G/12KT1 - output on changeover contact
Dimensions
See diagram
Weight
0.341 kg
Standards compliance
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Back-up protection device
Without
×
Description:
Type 1+2 PV surge protector
Standards compliance:
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification:
EAC
Technology:
VG Technology (MOV+GSG)
Remote signaling of disconnection:
Option DS50VGPVS-1000G/12KT1 - output on changeover contact
SPD type :
1+2
Network:
PV network 1000 Vdc
Max. PV operating voltage:
1200 Vdc
Residual Current :
None
Max. discharge current :
40 kA
Total Maximum discharge current :
60 kA
Impulse current by pole :
6.25 kA
CITEL
Reference:
DS50VGPV-1000G/12KT1
Part Number:
482303
Or equivalent
Read more