CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
Photovoltaic
Type 2 PV surge protector
DS50PVS-1000G/51
Type 2 PV surge protector
DS50PVS-1000G/51
Part Number
480391
Type 2 surge protector for PV
In : 15kA / Imax : 40kA
Pluggable
Remote signaling
UL1149 ed.5 certified
IEC 61643-31, EN 61643-31, EN 50539-11, UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
DS50PV/51 are type 2 surge protectors are designed to protect against lightning surge voltages in photovoltaic power supply network. Based on the use of specific varistors, providing a protection in common mode or common and differential mode.
Select another reference:
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
PV network 1000 Vdc
Nominal PV voltage
Uocstc
1000 Vdc
Max. PV operating voltage
Ucpv
1200 Vdc
Residual Current
Leakage current to Ground
Ipe
None
PV Permanent Operating current
Current consumption at Ucpv
Icpv
< 0.1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
15 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
40 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
60 kA
Current withstand short circuit PV
Iscpv
15 000 A
Connection mode(s)
+/-/PE
Protection mode(s)
Common/Differential mode
Protection level +/-
@ In (8/20µs)
Up
4.6 kV
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
2.6 kV
Technology
MOV+GDT
Connection to Network
By screw terminals: 2.5-25mm² / by bus
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection SPD of the PV line
Disconnection indicator
2 mechanical indicators
Spare module(s)
DSM50PV-1000G/51
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram
Weight
0.278 kg
Standards compliance
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Back-up protection device
Without
×
Description:
Type 2 PV surge protector
Standards compliance:
IEC 61643-31 / EN 61643-31 / EN 50539-11 / UL1449 ed.5
Certification:
EAC
Technology:
MOV+GDT
Remote signaling of disconnection:
Output on changeover contact
SPD type :
2
Network:
PV network 1000 Vdc
Max. PV operating voltage:
1200 Vdc
Residual Current :
None
Max. discharge current :
40 kA
Total Maximum discharge current :
60 kA
CITEL
Reference:
DS50PVS-1000G/51
Part Number:
480391
Or equivalent
Read more
Read more