CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Hard-wired AC surge protector
MSB10V-400 DE
Compact Type 2+3 hard wired surge protector
MSB10V-400 DE
Part Number
56110120
Compact type 2 + 3 surge protector
Wall mounting and hard wired connection
Status indicators
IP66
EN 61643-11 and IEC 61643-11, UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
MSB10 surge protectors Type 2 (or 3) are designed for effective protection of sensitive equipment, in addition to the surge protector installation (coordination surge protector). These surge protectors utilize a compact and economica scheme based varistors, to obtain a power flow relevant for secondary protection.
Select another reference:
MSB10-24
MSB10-31-230
MSB10-400 DE
MSB10C-400
MSB10V-120
MSB10V-400 DE
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2+3
Network
230 V single-phase
AC system
TT-TN
Nominal line voltage
Un
230 V
Max. AC operating voltage
Uc
277 Vac
Max. load current
@25°C
IL
16 A
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Operating current
Continious current at Uc
Ic
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
10 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
Common/Differential mode
Protection level
@ In (8/20µs)
Up
1.5 kV
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.5 kV
Protection level CM/DM
@ In (8/20µs)
Up mc/md
1.5 kV / 1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV+GDT
Connection to Network
By screw terminal
Mounting
Wall or plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection and AC line cut-off
Disconnection indicator
Green LED OFF
Voltage/operating indicator
Green Led ON
Dimensions
See diagram
Weight
0.1 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
UL Recognized
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
×
Description:
Compact Type 2+3 hard wired surge protector
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
UL Recognized
Technology:
MOV+GDT
SPD type :
2+3
Network:
230 V single-phase
AC system:
TT-TN
Max. AC operating voltage :
277 Vac
Max. discharge current :
10 kA
Protection level :
1.5 kV
Admissible short-circuit current:
10 000 A
CITEL
Reference:
MSB10V-400 DE
Part Number:
56110120
Or equivalent