CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 DC surge protector
DDC30CS-20-65
DC power surge protector Type 2 - 48 Vdc
DDC30CS-20-65
Part Number
828310121
Type 2 DC power surge protector
Compact design
Imax: 30 kA
Pluggable module
Remote signaling
Low Up protection level
Compliance prIEC 61643-41 and UL1449 ed.5
Datasheet
Installation Sheet
Tender specifications
Contact Us
The technology based on high energy varistor equipped with thermal disconnection mechanism offers protection efficiency and and a maximal reliability. High-energy varistor technology combined with disconnectors, provides maximum protection efficiency and reliability. The Type 2 DDCC version is particularly compact and available for voltages from 12 to 350 Vdc.
Select another reference:
DDC20CS-20-24
DDC20CS-20-38
DDC30CS-20-65
DDC40CS-20-100
DDC40CS-20-125
DDC40CS-20-150
DDC40CS-20-180
DDC40CS-20-275
DDC40CS-20-350
DDC40CS-20-460
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
DC network 48 Vdc
Nominal PV voltage
Uocstc
48 Vdc
Max. AC operating voltage
Uc
50 Vac
Max. PV operating voltage
Ucpv
65 Vdc
Max. DC operating voltage
Uc
65 Vdc
Max. load current
@25°C
IL
20 A
Residual Current
Leakage current to Ground
Ipe
< 0.1 mA
PV Permanent Operating current
Current consumption at Ucpv
Icpv
< 0.1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
15 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
30 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
60 kA
Current withstand short circuit PV
Iscpv
1000 A
Connection mode(s)
+/-/PE
Protection level +/PE (-/PE)
@ In (8/20µs)
Up
300 V
Admissible short-circuit current
Isccr
10 000 A
Network type
DC
Technology
MOV
Connection to Network
By screw terminals: 1.5-10mm² (actives wires) and 2.5-25mm² (ground)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Disconnection from DC network
Disconnection indicator
1 mechanical indicator - Red/Green
Spare module(s)
MDDC30C-20-65
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 1TE (EN43880)
Weight
0.103 kg
Standards compliance
prIEC 61643-41 and UL1449 ed.5
Thermal disconnector
Internal
Back-up protection device
50 A min. - 125 A max. - Fuses Type gG
×
Description:
DC power surge protector Type 2 - 48 Vdc
Standards compliance:
prIEC 61643-41 and UL1449 ed.5
Technology:
MOV
Remote signaling of disconnection:
Output on changeover contact
SPD type :
2
Network:
DC network 48 Vdc
Max. AC operating voltage :
50 Vac
Max. PV operating voltage:
65 Vdc
Max. DC operating voltage:
65 Vdc
Residual Current :
< 0.1 mA
Max. discharge current :
30 kA
Total Maximum discharge current :
60 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
DDC30CS-20-65
Part Number:
828310121
Or equivalent