CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
LED
Standard surge protection plate/wall
MLP1-230L-P/20K
Surge protector for LED lighting system Class 1
MLP1-230L-P/20K
Part Number
721213
Specially developed spd with combined protection for 2-phase power supply (control phase):
Many variants available depending on application
With screw terminals or cable wiring
IP65 versions
For protection class I or II application
Developed for Uoc: 20 kV and Imax: 20 kA for highest outdoor requirements according to IEEE & ANSI
Optical error signalling
Datasheet
Installation Sheet
Tender specifications
Contact Us
The MLP range is a comprehensive series of AC surge protectors dedicated to LED lighting system. Some versions are equipped with an extra dataline surge protection (RS485 or DALI) in order to provide a full solution for LED systems with transmission features. By this way the MLP range is able to provide all the existing configurations with an efficient solution . MLP surge protectors are based on a powerful association of MOV and GDT components, able to protect LED system against huge surges without disconnection. In the worse case, the SPD will fail in safety condition. Indication of the SPD failure is performed through power supply cut off and/or through remote signaling feature.
Select another reference:
MLP1-230L-W
MLP1-230L-W-2L
MLP1-230L-W/RS
MLP2-230L-W-2L
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2 (or 3)
Network
220-240 V Single-phase
AC system
TT-TN
Nominal line voltage
Un
230-277 Vac
Max. AC operating voltage
Uc
320 Vac
Max. frequency
f max.
10 MHz
Max. load current
@25°C
IL
5 A
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
10 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
20 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
20 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
20 kV
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.5 kV
Protection level CM/DM
@ In (8/20µs)
Up mc/md
1.5 kV / 1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
MOV+GDT
Connection to Network
By screw terminal: 1.5mm² max.
Mounting
On plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection and AC line cut-off
Disconnection indicator
LED green OFF and AC network cut-off
Voltage/operating indicator
Green Led ON
Remote signaling of disconnection
No
Dimensions
See diagram
Weight
0.086 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
×
Description:
Surge protector for LED lighting system Class 1
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Technology:
MOV+GDT
Remote signaling of disconnection:
No
SPD type :
2 (or 3)
Network:
220-240 V Single-phase
AC system:
TT-TN
Max. AC operating voltage :
320 Vac
Residual Current :
None
Max. discharge current :
20 kA
Total Maximum discharge current :
20 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
MLP1-230L-P/20K
Part Number:
721213
Or equivalent