CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
LED
VG Technology LED SPD
MLPX1VG-230L-W
Ultra Compact Type 2+3 hard wired surge protector
MLPX1VG-230L-W
Part Number
711294
Ultra compact Type 2+3 hard wired surge protectors
Wall mounting and hard wired connection
VG Technology
No aging
Bracket breakable
Protection rating : IP67
Disconnection signaling by indicator
AC disconnection in case of end of life
EN 61643-11, IEC 61643-11 and UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
Select another reference:
MLPX1VG-230L-W
MLPX1VG-230L-W/IP20
MLPX2VG-230L-W
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2+3
Network
230-277 V Single-phase
AC system
TT-TN
Nominal line voltage
Un
230 V
Max. AC operating voltage
Uc
320 Vac
Max. load current
@25°C
IL
10 A
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac withstand
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms disconnection
Residual Current
Leakage current to Ground
Ipe
None
Nominal discharge current
15 x 8/20 µs impulses
In
5 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
10 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
20 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
10 kV
Withstand on overvoltages IEEE C62.41.1
10 kV / 10 kA
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.5 kV
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.5 kV
Admissible short-circuit current
Isccr
10 000 A
Technology
VG Technology (MOV+GSG)
Connection to Network
By wires: 1.5mm² (L/N) and 2.5mm² (PE)
Mounting
Wall or plate
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP67
Failsafe mode
Disconnection and AC line cut-off
Disconnection indicator
LED green OFF and AC network cut-off
Voltage/operating indicator
Green Led ON
Remote signaling of disconnection
No
Dimensions
See diagram
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
×
Description:
Ultra Compact Type 2+3 hard wired surge protector
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
EAC
Technology:
VG Technology (MOV+GSG)
Remote signaling of disconnection:
No
SPD type :
2+3
Network:
230-277 V Single-phase
AC system:
TT-TN
Max. AC operating voltage :
320 Vac
Residual Current :
None
Max. discharge current :
10 kA
Total Maximum discharge current :
20 kA
Admissible short-circuit current:
10 000 A
CITEL
Reference:
MLPX1VG-230L-W
Part Number:
711294
Or equivalent
Read more
Read more