PV-DC-Junction box

GAK6.K4x16.K4x16.51VG-1
Part Number 158607
GAK6.K4x16.K4x16.51VG-1
  • Generator junction box for 1 MPP tracker / 4 strings
  • Integrated surge protection device
  • Protection class IP65
  • Connection via spring terminals

With the generator junction boxes of the GAK6 series, CITEL offers a solution to protect photovoltaic systems of any kind against the effects of lightning and overvoltages. The GAK6 series is designed to protect up to 6 MPP trackers and maximum system voltages (Ucpv) up to 1200 Vdc. Depending on the configuration, the GAK6 meet the normative requirements for all types of buildings with or without external lightning protection system up to lightning protection class I (Iimp = 12.5 kA / pole (10/350)).


SPD type
IEC

2

Network

PV network 1000 Vdc

Nominal DC voltage
Un-dc

1000 Vdc

Max. PV operating voltage
Ucpv

1200 Vdc

Rated insulation voltage
Ui
Ui

1000 Vdc

Rated current
InA
InA

6x 60 A

Rated string current
InC

6x 40 A

Input / per MPPT

Spring clamp terminals / 4x6-16mm²

Output / per MPPT

Spring terminals / 4x6-16mm²

Ground connection terminal

Spring clamp terminals / 16mm²

Cable gland

Metric / 12x M40 (Ø 16-28mm) / 1x M20 (Ø 6-13mm)

Housing material

UV and ozone resistant, fiberglass reinforced polycarbonate

Dimensions

WxHxD (mm): 847 x 615 x 330

Ambient temperatures

Indoor: -5°C to max. +40°C (+35°C 24h average) / Outdoor: -25°C to max. +40°C (+35°C 24h average)

Humidity

Indoor: max. 50% at +40°C, max. 90% at 20°C (non-condensing) / Outdoor: 95% for a short time at +25°C (non-condensing)

Protection rating

IP 65

Protection class

Class II

Impact resistance

IK 8

Pressure compensation element

Existing

Standards compliance

DIN EN 50539-11