CITEL
Test Facilities
Jobs & Career
About us
Locations
GTC
Lightning Surges
Citel's VG Technology
International Standards
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Products
AC Power
Radiocommunication
Telecom
Miscellaneous
GDT
Dataline
Photovoltaic
LED
Applications
Security Systems
Wind Turbine Installation
Industrial Installation
Datacenter
Surge protection for LED-lighting systems
Photovoltaic installations
Gas Discharge Tubes and Gas Filled Spark Gaps
Surge protection for E-mobility
Surge protection for cell phone communication
Water treatment
Services
Information
Order form
Selection guide
Partner
Toggle Dropdown
Contact Citel
Privacy policy
Our partners in Europe
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
GDT
Accessories
Telecom
DIN Rail Telecom/Data surge protector
DLUH-48D3
1-pair monobloc Data surge protector
DLUH-48D3
Part Number:
640704
For DIN rail mounting
Monobloc housing
1-pair
Max. line current 2.4 A
Un: 48 V
Transmission an protection of shield wire
IEC 61643-21 compliance
UL497A
Datasheet
Tender specifications
Contact Us
DLUH surge protectors are designed to protect, against surge voltages due to lightning, terminals equipment connected to industrial buses, telecom lines or datalines. These surge protectors must be installed on symmetrical DIN rail and are available for most of the transmission lines: line voltage from 6 to 170V, bitrate up to 10 Mbit/s. These products are 1-pair surge protectors and are made with DIN rail monobloc enclosure
Select another reference:
DLUH-06D3
DLUH-06DBC
DLUH-12D3
DLUH-170
DLUH-24D3
DLUH-48D3
DLUH-48DBC
Electrical Properties
Mechanical Properties
Norms
Schemas
Network
48 V line, ISDN-T0, Profibus-PA
Nominal line voltage
Un
48 V
Max. DC operating voltage
Uc
53 Vdc
Max. frequency
f max.
> 3 MHz
Insertion loss
< 1 dB
Max. load current
IL
2.4 A
Max. discharge current
Imax
20 kA
Line inductance
No
Protection mode(s)
Common/Differential mode
Protection level
Up
70 V
Max. capacitance
C
< 50 pF
Impulse current
Iimp
5 kA
Nominal discharge current
In
5 kA
Line resistance
0 Ohm
Technology
GDT+Clamping diode
SPD configuration
1-pair+shielded
Connection to Network
By screw terminal: cross section 0.4-1.5mm²
Format
DIN box
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Outdoor application
No
Failsafe mode
Short-circuit - transmision cut-off - fault mode 2
Disconnection indicator
Transmission interrupt
Remote signaling of disconnection
No
Max. number of pairs
1
Dimensions
See diagram
Standards compliance
IEC 61643-21 / EN 61643-21 / UL497A
Certification
UL listed
×
Read more