CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2 AC surge protector
DAC1-13S-11-320
Type 1+2 AC surge protector single-phase
DAC1-13S-11-320
Part Number
821710342
Type 1 + 2 AC surge protector
In : 20 kA
Iimp : 12.5 kA
Pluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 certified
UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DAC1-13 is an extreme duty Type 1+2 pluggable SPD designed to protect AC powerline at the main switchboard of an installation equipped with lightning rod. The technology ‘Multi-varistor” allows a very high discharge current capability in small dimensions and the best possible behavior to the AC network (no follow current). In the light of their high discharge capability, the DAC1-13 surge protectors are especially compact and are available in multipolar versions to protect single or 3-phase AC networks.
Select another reference:
DAC1-13S-10-150
DAC1-13S-10-275
DAC1-13S-10-320
DAC1-13S-10-440
DAC1-13S-11-150
DAC1-13S-11-275
DAC1-13S-11-320
DAC1-13S-20-150
DAC1-13S-20-275
DAC1-13S-20-320
DAC1-13S-20-440
DAC1-13S-30-150
DAC1-13S-30-275
DAC1-13S-30-320
DAC1-13S-30-440
DAC1-13S-31-150
DAC1-13S-31-275
DAC1-13S-31-320
DAC1-13S-40-150
DAC1-13S-40-275
DAC1-13S-40-320
DAC1-13S-40-440
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Network
230 V single-phase
AC system
TT-TN
Max. AC operating voltage
Uc
320 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
100 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
25 kA
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection mode(s)
L/N and N/PE
Protection level
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
Up L/N
1.6 kV
Protection level N/PE
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
Up N/PE
1.5 kV
Residual voltage L/N at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1.2 kV
Protection level N/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1.2 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
MOV
SPD configuration
Single phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDAC1-13-320 + MDAC1-25G-xxx
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 2TE (EN43880)
Weight
0.281 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuse assembly: SFD1-13S-11 / or 125 A min. - 315 A max. - Fuses Type gG
×
Description:
Type 1+2 AC surge protector single-phase
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
MOV
SPD configuration:
Single phase
Remote signaling of disconnection:
Output on changeover contact
SPD type :
1+2
Network:
230 V single-phase
AC system:
TT-TN
Max. AC operating voltage :
320 Vac
Residual Current :
None
Max. discharge current :
50 kA
Total Maximum discharge current :
100 kA
Impulse current by pole :
12.5 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC1-13S-11-320
Part Number:
821710342
Or equivalent
Read more
Read more