CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2 AC surge protector
DS504E-230/G
Type 1+2 AC surge protector - 3-phase+N
DS504E-230/G
Part Number
5042301
Type 1 + 2 multipolar AC surge protector
Iimp total : 100 kA (10/350µs impulse)
Imax : 150 kA (8/20µs impulse)
Internal disconnections, status indicator and remote signaling
Conforme NF EN 61643-11, IEC 61643-11, UL1449 ed.5
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DS500E range of surge protectors are Type 1 + 2, very high power, they are intended to be installed at the entry of the Low Voltage installation. They are used to protect single-phase, three-phase or three-phase + Neutral networks in common mode or in common and differential mode. The 'Multi-Varistor' technology used allows the best possible behavior for the LV network (no follow-on current). The DS500E range is installed on a DIN Rail and has a double connection for the active conductor, which allows an optimized connection to the network.
Select another reference:
DS500E-230
DS500E-320
DS500E-400
DS502E-230
DS502E-230/G
DS502E-320
DS502E-320/G
DS502E-400
DS503E-230
DS503E-320
DS503E-400
DS504E-230
DS504E-230/G
DS504E-320
DS504E-320/G
DS504E-400
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2
Network
230/400 V 3-phase+N
AC system
TT-TNS
Nominal line voltage
Un
230 Vac
Max. AC operating voltage
Uc
255 Vac
Max. load current
if series connection
IL
100 A
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Temporary Over Voltage N/PE (TOV HT)
Without disconnection or with safety disconnection
UT
1200 V/300A/200 ms withstand
Operating current
Continious current at Uc
Ic
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
50 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
200 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
50 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
100 kA
Specific energy by pole
max. withstand 10/350 µs
W/R
625 kJ/ohm
Connection mode(s)
L/N and N/PE
Protection mode(s)
Common/Differential mode
Protection level L/N
@ In (8/20µs)
Up L/N
1.8 kV
Protection level N/PE
@ In (8/20µs)
Up N/PE
1.5 kV
Admissible short-circuit current
Isccr
50 000 A
Technology
MOV
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 6-35mm² / by bus
Format
1-pole modular box assembled
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole
Remote signaling of disconnection
Output on changeover contact
Dimensions
See diagram
Weight
2.09 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuses Type gG - 500 A
×
Description:
Type 1+2 AC surge protector - 3-phase+N
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
EAC
Technology:
MOV
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
Output on changeover contact
SPD type :
1+2
Network:
230/400 V 3-phase+N
AC system:
TT-TNS
Max. AC operating voltage :
255 Vac
Max. discharge current :
200 kA
Impulse current by pole :
50 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DS504E-230/G
Part Number:
5042301
Or equivalent