CITEL
About us
Locations
Test Facilities
Jobs & Career
GTC
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Citel's VG Technology
CITEL CTC-Technology
International Standards
Products
AC Power
Photovoltaic
LED
Dataline
Radiocommunication
Telecom
GDT
Miscellaneous
Applications
Datacenter
Surge protection for LED-lighting systems
Surge protection for cell phone communication
Security Systems
Industrial Installation
Wind Turbine Installation
Surge protection for photovoltaic systems
Water treatment
Surge protection for E-mobility
Surge protection for meter locations
Services
Information
Selection guide
Order form
Partner
Toggle Dropdown
Contact Citel
Our partners in Europe
Privacy policy
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 2 AC surge protector
DACF25S-30-275
Type 2 AC surge protector - 3-phase - Integrated fuses
DACF25S-30-275
Part Number
821410223
Type 2 AC surge protector
In: 15 kA
Imax: 25 kA
Interne Disconnection device
Pluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 certified
UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
Type 2 DACF25 SPDs are used mainly for primary surge protection of single and 3-phase AC networks at the main switchboard. In addition to their thermal disconnector, the range is equipped with an internal fuse against short-circuit currents, which avoids the use of an external fuse or circuit-breaker as requested by standard. The operation of one of the both disconnectors will activate the indicator and the remote signalling (option). This compact solution simplifies the implementation and minimum space. The DACF25 surge protectors are designed to be used in a multipolar configuration to protect single-phase, 3-phase.
Select another reference:
DACF25S-10-150
DACF25S-10-275
DACF25S-10-320
DACF25S-10-440
DACF25S-11-150
DACF25S-11-275
DACF25S-20-150
DACF25S-20-275
DACF25S-20-320
DACF25S-20-440
DACF25S-30-150
DACF25S-30-275
DACF25S-30-320
DACF25S-30-440
DACF25S-31-150
DACF25S-31-275
DACF25S-31-320
DACF25S-31-440
DACF25S-40-150
DACF25S-40-275
DACF25S-40-320
DACF25S-40-440
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
230/400 V 3-phase
AC system
TNC
Max. AC operating voltage
Uc
275 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
335 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
440 Vac disconnection
Residual Current
Leakage current to Ground
Ipe
< 1 mA
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
15 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
25 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
75 kA
Connection mode(s)
L/PE
Protection level L/PE
@ In (8/20µs)
Up L/PE
1.25 kV
Residual voltage L/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
1 kV
Admissible short-circuit current
Isccr
100 000 A
Technology
MOV
SPD configuration
3-phase
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDACF25-275
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 3 TE (EN43880)
Weight
0.302 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
internal (equivalent AC rating : 40 A, gG Type)
Integrated fuses
Yes
×
Description:
Type 2 AC surge protector - 3-phase - Integrated fuses
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
MOV
SPD configuration:
3-phase
Remote signaling of disconnection:
Output on changeover contact
SPD type :
2
Network:
230/400 V 3-phase
AC system:
TNC
Max. AC operating voltage :
275 Vac
Residual Current :
< 1 mA
Max. discharge current :
25 kA
Total Maximum discharge current :
75 kA
Admissible short-circuit current:
100 000 A
Integrated fuses:
Yes
CITEL
Reference:
DACF25S-30-275
Part Number:
821410223
Or equivalent
Read more