CITEL
Test Facilities
Jobs & Career
About us
Locations
GTC
Lightning Surges
Citel's VG Technology
International Standards
Lightning and Transient overvoltages
The origin of overvoltages
Keraunic levels
Effects of lightning
Surge Protection
Products
AC Power
Radiocommunication
Telecom
Miscellaneous
GDT
Dataline
Photovoltaic
LED
Applications
Security Systems
Wind Turbine Installation
Industrial Installation
Datacenter
Surge protection for LED-lighting systems
Photovoltaic installations
Gas Discharge Tubes and Gas Filled Spark Gaps
Surge protection for E-mobility
Surge protection for cell phone communication
Water treatment
Services
Information
Order form
Selection guide
Partner
Toggle Dropdown
Contact Citel
Privacy policy
Our partners in Europe
Impress
Toggle Dropdown
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
GDT
Accessories
AC Power
Type 2 AC surge protector
DACF25S-31-440
Type 2 AC surge protector - Single-phase
DACF25S-31-440
Part Number:
821410444
Type 2 AC surge protector
In : 15 kA
Imax : 25 kA
Interne Disconnection device
Pluggable module for each phase
Remote signaling
EN 61643-11, IEC 61643-11 and UL1449 ed.5 compliance
Datasheet
Installation Sheet
Tender specifications
Contact Us
Type 2 DACF25 SPDs are used mainly for primary surge protection of single and 3-phase AC networks at the main switchboard. In addition to their thermal disconnector, the range is equipped with a internal fuse against short-circuit currents, which avoidsthe use of a external fuse or circuit-breaker as requested by standard. The operation of one of the both disconnectors will activate the indicator and the remote signalling (option). This compact solution simplifies the implementation and minimum space. The DACF25 surge protectors are designed to be used in a multipolar configuration to protect single-phase, 3-phase.
Select another reference:
DACF25S-10-150
DACF25S-10-275
DACF25S-10-320
DACF25S-10-440
DACF25S-11-150
DACF25S-11-275
DACF25S-11-320
DACF25S-20-150
DACF25S-20-275
DACF25S-20-320
DACF25S-20-440
DACF25S-30-150
DACF25S-30-275
DACF25S-30-320
DACF25S-30-440
DACF25S-31-150
DACF25S-31-275
DACF25S-31-320
DACF25S-31-440
DACF25S-40-150
DACF25S-40-275
DACF25S-40-320
DACF25S-40-440
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
2
Network
230 V single-phase
AC system
TT-TN
Max. AC operating voltage
Uc
440 Vac
Temporary Over Voltage (TOV) Charasteristics - 5 sec.
UT
580 Vac withstand
Temporary Over Voltage (TOV) Charasteristics - 120 mn
UT
770 Vac disconnection
Residual Current
Ipe
None
Follow current
If
None
Nominal discharge current
In
15 kA
Max. discharge current
Imax
25 kA
Total Maximum discharge current
Imax Total
50 kA
Connection mode(s)
L/N and N/PE
Protection level L/N
Up L/N
2 kV
Protection level N/PE
Up N/PE
2 kV
Residual voltage L/N at 5 kA
Up-5kA
1.5 kV
Protection level N/PE at 5 kA
Up-5kA
1.5 kV
Admissible short-circuit current
Isccr
100 000 A
Technology
MOV+GDT
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDACF25-320+MDACG-320
Remote signaling of disconnection
Output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 2TE (EN43880)
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Fuses
Integrated Fuse
Integrated fuses
Yes
×